R4-g Touch LUNG VENTILATOR
The ventilator PR4-g Touch is among the most complete lung ventilators of the market and offers all the ventilation modes required to care of Adult, Pediatric and Neonatal patients in addition to its respiratory mechanics menu for various diagnoses. It offers high ventilation quality suited to every patient with quick and safe adjustments of each ventilation parameter, providing the professional with a pleasant work which allows greater patient care.
VENTILATION MODES
Adult / Pediatric
- VCV Assisted/Controlled
- PCV Assisted/Controlled
- PSV/CPAP
- PRVC
- SIMV (VCV) + PSV
- SIMV (PCV) + PSV
- Biphasic Pressure (APRV+PSV)
- NIV (Leakage compensation in all ventilatory modes)
Ventilation Backup:
- VCV
- PCV
Neonatal
- PCV Assisted/Controlled
- PSV/CPAP
- SIMV (PCV) + PSV
- Continuous Flow
- Nasal CPAP
Ventilation Backup:
- PCV
GRAPHICAL INTERFACE
Initial Setup
- Patient Selection
- Gender Selection
- Height Selection
- Automatic Theoretical Weight Calculation
- Ventilation Level per mL/kg
- Artificial Airway Type
- Humidification Type
- Circuit Compliance Measurement
- Last Patient Function
Operational Visualization
- Selection of the monitored
- ventilation variables
- Battery Charge Indicator
- Pressure Bargraph
Customizable selection of up to 5 simultaneous graphics (Adult and Pediatric):
- Pressure/Time
- Flow/Time
- Volume/Time
- Volume/Pressure Loop
- Flow/Volume Loop
- Pressure/Flow Loop
- Plethysmography
- ETCO2 /Time
Customizable selection of up to 2 simultaneous graphics (Neonatal):
- Pressure/Time
- Flow/Time
- Volume/Time
- Plethysmography
- ETCO2 /Time
PARAMETERS
Monitored Parameters
- Peak Pressure
- Plateau Pressure
- Mean Pressure
- Base Pressure (PEEP)
- Peak Inspiratory Flow
- Peak Expiratory Flow
- Expiratory Tidal Volume
- Minute Volume
- Respiratory Frequency
- I:E
- Ti/Ttot
- Inspiratory Time
- Expiratory Time
- Tendency Graphics
- Alarms Log
Lung Mechanics
- Inspiratory Resistance
- Expiratory Resistance
- Dynamic Compliance
- Static Compliance
- AutoPEEP
Optionals
- Heart Rate
- Plethysmography
- Inspired CO2
- SpO2/FiO2
- ETCO2
- SpO2
- FiO2
Programmable Parameters
- FiO2
- 50% up to 100%
-
Flow Waveform:
- Square
- Sinusoidal
- Ascending
- Descending 100%
- Descending 50%
- Rise Time
- Inspiratory Time
- Respiratory Frequency
- Tidal Volume
- Minute Volume
- Expiratory Sensibility
- Controlled Pressure
- Support Pressure
- PEEP
- Sensibility:
- Pressure/Flow
- Apnea Time
- Inspiratory Pause
- Sigh
Auxiliary Functions
- Oxygen 100%
- Manual Inspiratory Trigger
- Graphics Freeze
ALARMS
Automatic
- Low Battery
- Power Failure
- Low O2 Pressure
- Interrupted Cycle
- Inverted I:E Rati
Request a Quote
Programmable
- Max. Respiratory Frequency
- Max. Exhaled Minute Volume
- Min. Exhaled Minute Volume
- Max. Exhaled Tidal Volume
- Min. Exhaled Tidal Volume
- Maximum Pressure
- Minimum Pressure
- Apnea
- PEEP